Dose received
–% of the limit
LEX,8h – · LAeq – · LCpeak –
No measurement yet
Not calibrated: indicative values
If it lasts…
Now –LEX,8h–
% of the limit–
Measure a few minutes of a typical moment.
The day's dose if the measured noise lasts this long, then quiet. Only valid if the measured moment is like the rest of the day.
The sound stays on your device: nothing is sent.
The screen stays on while measuring: plug the phone in for a long session.
The one for your region is chosen by default.
Provinces have their own rules, often 85 dBA: this one only applies to federal workplaces.
In Europe, 100 % = 85 dB(A): the 87 dB(A) limit value is judged with hearing protection worn, and the phone measures without it.
If you know the difference from a reference sound level meter, set it here; the same setting applies to the whole dose.
What this dosimeter can and cannot do
This is not a certified dosimeter: it does not replace your employer's measurement. A real dosimeter is worn on the shoulder, near the ear; a phone in a pocket hears muffled sound and underestimates the dose: put it near you, uncovered. Its microphone often saturates between 100 and 120 dB, and without calibration the error can reach several decibels. The dose does not take hearing protection into account. If the screen turns off, the iPhone cuts the microphone and Android guarantees nothing: the page then counts a gap and says so.